- REALE
- CHINA
- 15 days after deposit
- 10 sets one month
Huanrui had obtained an improved walk-in test chamber patent certificate.Huanrui has a team of experienced engineers to design drawings at any time according to customer needs,and provide complete solutions according to customer needs.
Walk-in test chamber
Application
The Walk-in climatic test chamber is suitable for testing various performance indicators of aerospace products, information electronics instruments, materials, electrical and electronic products, and various electronic components in high and low temperature or hot and humid environments.
Electrical control design
The electrical control part of walk-in test chamber is installed in a separate box, which is completely independent of other functional parts of the test box such as cooling, heating, and waterway, to avoid leakage of the power distribution cabinet due to failure of other functional parts of the test box.
Custom Services
The temperature range, humidity range, and volume of walk-in test chamber can be individually designed according to the needs of different customers.
Standard specification of walk-in test chamberfor reference.
Model | RHPW-4 | RHPW-6 | RHPW-8 | RHPW-13 | RHPW-17 | RHPW-21 |
System | Balanced temperatuer & humidity control system | |||||
Testing temperature range | R.T-65℃~+120℃ | |||||
Humidity range | 20%-95%RH | |||||
Temperature fluctuation | ±0.5℃ | |||||
Humidity fluctuation | ±2.5%RH | |||||
Temperture uniformity | ±2.0℃ | |||||
Humidity uniformity | ±5.%RH | |||||
Temperture deviation | ±2℃ | |||||
Humidity deviation | ±3%RH (≥75%) ±5%RH(<75%) | |||||
Heat up time | 20℃~+80℃ within 60 minutes | |||||
Pull down time | 20℃~-55℃,-40℃,-30℃,-20℃,-10℃ within 120 or 90 or 60 minutes. | |||||
Interior volume(m3) | 9.04 | 12.9 | 16.78 | 27.09 | 35.21 | 43.34 |
Interior material | SUS#304 Stainless steel plate | |||||
Exterior material | Model steel | |||||
Insulation material | Rigid polyerethane foam +glass fibre | |||||
Floor bearing load | 500Kg/m3 | |||||
Refrigeration system | Air cooled (Water cooled type is option) | |||||
Cascade type, hermetic/semitight compressor,CFC free refrigerant | ||||||
Controller | Color LCD screen in English/Chinese, programing,communicating function | |||||
Safety devices | No welding wire switch,compressor overheating and over current protection,over temperature protection, blower overload protection,dry heating machine protector,low water protection,fault warning system. | |||||
Power | AC380±10% 50HZ 3 phase 4 ires+ground wires |