- REALE
- DONGGUAN,CHINA
- 20 days after payment
- 500 PCS/YEAR
Product Name: Short Circuit Test Machine
Function: testing battery safety performance
Remote Control:
1). Long distance wireless control
2). Reliable, stable, has the self-locking and interlocking functions, strong anti-interference ability, long service life
Pressure gauge :
1) Measuring voltage: 0-100V to ensure test accuracy;
2) Display accuracy: F.S ±0.2% rdg ±1digit;
3) Action: 2 points
Ammeter:
1) Measuring current: 0-2000A and 0-1000A DC
2) Display accuracy: F.S ±0.2% rdg ±1digit;
3) Action: Two-fold integration.
Basic configuration:
1) The whole battery short-circuit tester consists of a large current short-circuit contactor, a remote controller, a voltmeter, and an ammeter;
2) must be equipped with accessories: 1000A (or 2000A) test copper and so on.
Short Circuit Test Machine
Features:
1) The rated working current is 1000A (or 2000A) DC, equipped with a serial magnetic blower vertical partition clay extinguishing arc extinguishing system;
2) The overall structure of the plane layout, the electromagnetic system and the main contact arc extinguishing system are respectively fixed on the mounting base frame, and the angularly rotating beater type electromagnetic system and the double-winding attraction coil are used to install the pressure edge device on the rotating edges and corners;
3 ) The main contacts are made of copper. Low contact contact resistance and fast response
4 )Contactor action is reliable, safe, long life, easy maintenance.
SPECIFICATIONS | |||
Working voltage | AC 220V 50Hz-60Hz | ||
Impact voltage | AC 1kv/1.2-50μs(peak) 1min | ||
Maximum battery voltage | 110V | ||
DC response time | ≤5μs | ||
Maximum short circuit current | 1000A(2000A) | ||
Internal resistance of device | ≤100mΩ | ||
Movement time | pull in time/release time 30ms | ||
Performance characteristic | Cold pull-in voltage 66%Us Cold release voltage 30%Us, 5%Us | ||
Mechanical life | 300 thousand times | ||
Working environment | Temperature -10°C~100°C Humidity 10~90% without condensation |