Sand test chamber simulate natural world sand clamite destructive to the products suit for test seal performance of
products,mainly used for the IP5X and IP6X two levels of tests specified in the shell protection class standard.
Character:
The interior chamber used stainless steel, and the outer used cold-rolled sheet with electrostatic spraying.
With import intelligent temperature control table.
Small type programmable controller, the system has the protection function.
Mess diameter: 50μm
Wire spacing: 75μm
Sand And Dust Resistance Environmental Test Chamber
apply for testing of prevent sand into seal component and shell of electric and electronic products,
auto, motorbike accessory at sand environmental.To test the performance of the use, storage, and transportation of electrical and electronic products, automobiles, motorcycle parts, and seals in sand and dust environments.
Parameter:
Model | RDH-80 | RDH-150 | RDH-225 | RDH-408 | RDH-800 | |
Temperature range | 20℃~80℃ | |||||
Air Duct System | Non-layered vertical cyclical airflow | |||||
Sand plate size | 150μm~850μm | |||||
Dust size | <149μm | |||||
Sand dust composition | Dry talcum power, portland cement | |||||
Nominal diameter metal mesh | 50μm | |||||
Line spacing between lines | 75μm | |||||
Blowing sand capacity | 2.2±0.5g/m3(Blowing sand speed:18~29m/s) | |||||
Blow dust capacity | 10.6±7.0g/m3(Blowing dust speed:0.5~8.9m/s) | |||||
Controllor | Samll programmable time controller | |||||
Internal dimension(CM) | W | 40 | 50 | 50 | 60 | 80 |
H | 50 | 60 | 60 | 75 | 100 | |
D | 40 | 50 | 75 | 60 | 100 | |
Internal dimension(CM) | W | 100 | 105 | 115 | 115 | 160 |
H | 143 | 150 | 97 | 175 | 190 | |
D | 85 | 110 | 80 | 140 | 140 |